Analisa Intensitas Konsumsi Energi dan Sistem Pencahayaan pada Gedung Teknik Kimia Universitas Malikussaleh
Keywords:
Audits, Energy. IKE, Light system, SNI 2020.Abstract
Energy audits are a crucial step in energy management, providing an indication of a building's energy efficiency. This study, conducted in the Chemical Engineering Building at Malikussaleh University, aimed to evaluate electrical energy consumption by calculating energy consumption intensity (EKE), and to verify compliance with the 2020 Indonesian National Standards (SNI) for the lighting system. Data were collected through direct observation, interviews, and the analysis of documentation. The study focused on analysing lighting levels and electrical energy consumption, including calculating IKE. The results showed that lighting levels in most rooms did not meet SNI standards, with only the terrace area meeting the criteria. The building's daily energy consumption was found to be 402.8 kWh, with cooling loads accounting for the largest proportion. The IKE values for lighting and cooling on both floors of the building were below the required standard, indicating a lack of energy efficiency. The main factors influencing these results were inadequate lighting design, the use of inappropriate lamp types, and suboptimal maintenance of the lighting system. To improve energy efficiency, it is recommended that lamps are added or replaced with high-efficiency ones and that energy planning is improved based on a more comprehensive energy audit. This research contributes to improving energy efficiency in the education sector.
References
[1]. F. S. Desky, S. Hardi, R. Muchsin, and H. Rohana, “Intensitas Konsumsi Energi Listrik dan Analisa Peluang Hemat,” Jurnal Serambi Engineering, vol. 7, no. 1, pp. 104–108, 2022.
[2] P. K. Hanawati, B. M. Basuki, and E. S. Wirateruna, “Audit dan Rancangan Implementasi Manajemen Energi di Bangunan Gedung,” Jurnal Teknik Mesin dan Energi, vol. 6, no. 2, pp. 1–10, 2018.
[3] Badan Standardisasi Nasional, SNI 03-6196-2000: Prosedur Audit Energi pada Bangunan Gedung, Jakarta: BSN, 2000.
[4] P. K. Hanawati and B. M. Basuki, “Audit dan Rancangan Implementasi Penghematan Energi,” Prosiding Seminar Nasional Energi Terbarukan, pp. 1–8, 2018.
[5] M. S. A. Nugraha, M. Syukri, R. S. Lubis, and R. H. Siregar, “Audit Energi Listrik pada Gedung B Fakultas Teknik Universitas Negeri Medan,” Jurnal Energi dan Listrik, vol. 5, no. 1, pp. 1–10, 2023.
[6] J. Custer, “Analisis Audit Energi di Bengkel Las Politeknik Negeri Bengkalis,” Prosiding Seminar Nasional PAKAR, pp. 1–7, 2018.
[7] I. Habil, N. Aryanto, and P. A. Topan, “Audit Energi pada Gedung Orange dan Gedung Belakang Orange,” Jurnal Rekayasa Energi, vol. 9, no. 2, pp. 1–12, 2023.
[8] A. A. Rahmawati and S. Abduh, “Audit Energi Gedung Kampus A Universitas Muhammadiyah,” Jurnal Energi Terbarukan Indonesia, vol. 8, no. 1, pp. 1–9, 2023.
[9] J. R. Evans and W. M. Lindsay, The Management and Control of Quality, 8th ed., Canada: South-Western Cengage Learning, 2011.
[10] A. A. Rahmawati and S. Abduh, “Audit Energi Gedung Kampus A Universitas Muhammadiyah,” Jurnal Teknik dan Energi, vol. 8, no. 2, pp. 1–9, 2023.
[11] M. S. A. Nugraha, M. Syukri, R. S. Lubis, and R. H. Siregar, “Audit Energi Listrik pada Gedung B Fakultas Teknik,” Jurnal Energi dan Listrik, vol. 5, no. 2, pp. 15–24, 2023.
[12] F. S. Desky, S. Hardi, R. Muchsin, and H. Rohana, “Intensitas Konsumsi Energi Listrik dan Analisa Peluang Hemat,” Jurnal Serambi Engineering, vol. 7, no. 1, pp. 2–8, 2022.
[13] F. S. Desky, S. Hardi, R. Muchsin, and H. Rohana, “Intensitas Konsumsi Energi Listrik dan Analisa Peluang Hemat,” Jurnal Serambi Engineering, vol. 7, no. 1, pp. 2–8, 2022.
[14] D. Oktavia, Analisis Audit Energi Listrik pada Gedung Fakultas Teknik (Skripsi), Universitas Negeri Medan, 2023.
[15] M. S. A. Nugraha, M. Syukri, R. S. Lubis, and R. H. Siregar, “Audit Energi Listrik pada Gedung B Fakultas Teknik,” Jurnal Energi dan Listrik, vol. 5, no. 1, pp. 1–10, 2023.
[16] A. R. Hakim, B. Sukoco, and Gunawan, “Audit Energi Listrik pada Gedung Fakultas,” Jurnal Rekayasa Energi dan Mesin, vol. 4, no. 2, pp. 1–10, 2019.
[17] M. S. Samhuddin and Kadir, “Analisis Konsumsi Energi pada Kantor Pemerintahan,” Jurnal Teknologi Energi, vol. 5, no. 2, pp. 1–8, 2017.
[18] S. Riadi and E. Trigunadi, “Audit Energi untuk Mencapai Peluang Hemat Energi,” Jurnal Elektro Indonesia, vol. 6, no. 1, pp. 1–7, 2017.
[19] Badan Standardisasi Nasional, SNI 6197:2020: Konservasi Energi pada Sistem, Jakarta: BSN, 2020.
[20] W. S. P. Harris, P. Purwito, and A. R. Ashar, “Analisis Sistem Manajemen Audit Penggunaan Energi Listrik pada Bangunan Gedung,” Jurnal Energi dan Sistem Kelistrikan, vol. 10, no. 2, pp. 1–9, 2023.
[21] Badan Standardisasi Nasional, SNI 03-6575-2001: Tata Cara Perancangan Sistem Pencahayaan Buatan, Jakarta: BSN, 2001.
[22] P. K. Hanawati and B. M. Basuki, “Audit dan Rancangan Implementasi Penghematan Energi,” Prosiding Seminar Nasional Energi Terbarukan, pp. 1–6, 2018.
[23] M. S. A. Nugraha, M. Syukri, R. S. Lubis, and R. H. Siregar, “Audit Energi Listrik pada Gedung B Fakultas Teknik,” Jurnal Energi dan Listrik, vol. 5, no. 1, pp. 1–10, 2023.
[24] A. Prastyawan, “Analisis Audit Energi Listrik pada Gedung Jurusan Teknik,” Jurnal Rekayasa Elektro, vol. 6, no. 2, pp. 1–9, 2020.
[25] M. S. A. Nugraha, M. Syukri, R. S. Lubis, and R. H. Siregar, “Audit Energi Listrik pada Gedung B Fakultas Teknik,” Jurnal Energi dan Listrik, vol. 5, no. 1, pp. 1–10, 2023.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Teuku Multazam, Beni Maidika, Andik Bintoro (Author)

This work is licensed under a Creative Commons Attribution 4.0 International License.