Regenerasi Kinerja Fluks Membran PVDF Ultrafiltrasi Menggunakan Kombinasi Asam Sitrat & H2O2 Dalam Pengolahan Air Sungai Jagir

Authors

  • Kresna Setyawan Adhi Pamungkas Universitas Pembangunan Nasional "Veteran" Jawa Timur Author
  • Muhammad Abdus Salam Jawwad Universitas Pembangunan Nasional "Veteran" Jawa Timur Author

Keywords:

PVDF, Ultrafiltrasi, Fouling, Pemulihan Fluks, Pencucian Kimia

Abstract

Polyvinylidene fluoride (PVDF)-based ultrafiltration membranes are widely used because they can remove suspended and dissolved contaminants from water. However, fouling remains a major challenge, causing flux reduction and shortening the lifespan of the membrane. This study evaluated the performance of PVDF membranes when filtering Jagir River water, and assessed the effectiveness of stepwise washing with citric acid (C₆H₈O₇) and hydrogen peroxide (H₂O₂). Experiments were conducted at operating pressures of 1, 1.5 and 2 bar. Membrane flux was measured under four operating conditions: initial flux using distilled water (Jw1); river water flux before washing; flux using distilled water after washing (Jw2); and river water flux after washing. The results showed that Jw1 increased with increasing pressure, reaching a maximum value at 2 bar. However, river water filtration caused a significant decrease in flux due to fouling. Stepwise chemical washing partially recovered the flux, as indicated by the increases in Jw₂ and river water flux after washing. However, full recovery was limited by irreversible fouling. The highest Flux Recovery Ratio (FRR) value was obtained at 2 bar with a 6 wt% washing solution, indicating that the combination of high pressure and chemical treatment provides optimal performance recovery. Overall, the PVDF membrane can be effectively regenerated using citric acid and hydrogen peroxide; however, organic and inorganic mixed fouling limits total flux recovery.

References

M. El Batouti, N. F. Alharby, and M. M. Elewa, “Review of new approaches for fouling mitigation in membrane separation processes in water treatment applications,” Separations, vol. 9, no. 1, 2022, doi: 10.3390/separations9010001.

X. Du, Y. Shi, V. Jegatheesan, and I. Ul Haq, A review on the mechanism, impacts and control methods of membrane fouling in MBR system, vol. 10, no. 2. 2020. doi: 10.3390/membranes10020024.

M. Chheang, N. Hongprasith, C. Ratanatawanate, and J. Lohwacharin, “Effects of Chemical Cleaning on the Ageing of Polyvinylidene Fluoride Microfiltration and Ultrafiltration Membranes Fouled with Organic and Inorganic Matter,” Membranes, vol. 12, no. 3. 2022. doi: 10.3390/membranes12030280.

H. Z. Yasmin, “Efektivitas Kombinasi Konsentrasi Hidrogen Peroksida (H2O2) dan Waktu Kontak Sinar Ultraviolet-C Terhadap Penurunan Bakteri Coliform pada Limbah Cair RS PKU Muhammadiyah Surakarta,” J. Kesehat. Masy., vol. 11, no. 1, pp. 72–81, 2023, [Online]. Available: https://ejournal3.undip.ac.id/index.php/jkm/article/download/34578/28999

L. Xiang, M. Yuanyuan, C. Zhonglin, and Q. Shuhao, “A simple and effective method to adjust the size of micropores on the inner surface of Polyvinylidene fluoride hollow fiber membranes,” Polym. Eng. & Sci., vol. 63, no. 12, pp. 3998–4006, 2023, doi: https://doi.org/10.1002/pen.26500.

N. Alsawaftah, W. Abuwatfa, N. Darwish, and G. Husseini, “A comprehensive review on membrane fouling: Mathematical modelling, prediction, diagnosis, and mitigation,” Water (Switzerland), vol. 13, no. 9, 2021, doi: 10.3390/w13091327.

N. Hidayati, Mardiyono, and Wimpy, “Pemanfaatan larutan asam sitrat sebagai upaya penurunan kadar logam berat krom pada sayuran kubis,” vol. 11, no. 3, pp. 237–246, 2022, [Online]. Available: http://download.garuda.kemdikbud.go.id/article.php?article=3396069&val=29790&title=Pemanfaatan Larutan Asam Sitrat sebagai Upaya Penurunan Kadar Logam Berat Krom pada Sayuran Kubis

I. Ibrar et al., “Feasibility of H2O2 cleaning for forward osmosis membrane treating landfill leachate,” J. Environ. Manage., vol. 294, no. April, p. 113024, 2021, doi: 10.1016/j.jenvman.2021.113024.

U. Fathanah et al., “Sintesis, Karakterisasi dan Kinerja Membran Hidrofobik Menggunakan Polyvinyl Pyrrolidone (PVP) sebagai Aditif,” ALCHEMY J. Penelit. Kim., vol. 17, no. 2, p. 140, 2021, doi: 10.20961/alchemy.17.2.48435.140-150.

M. Al-Shaeli, S. J. D. Smith, S. Jiang, H. Wang, K. Zhang, and B. P. Ladewig, “Long-term stable metal organic framework (MOF) based mixed matrix membranes for ultrafiltration,” J. Memb. Sci., vol. 635, 2021, doi: 10.1016/j.memsci.2021.119339.

A. Fathurrahman, R. Arisandi, A. Fahrina, N. Arahman, and F. Razi, “Filtration performance of polyethersulfone (PES) composite membrane incorporated with organic and inorganic additives,” IOP Conf. Ser. Mater. Sci. Eng., vol. 1087, no. 1, p. 012049, Feb. 2021, doi: 10.1088/1757-899x/1087/1/012049.

G. Hu and Z. Wang, “The sedimentation probability model based on the particle size distribution and cake morphology in the cross-flow membrane process,” Chem. Eng. Sci., vol. 304, p. 121045, 2025, doi: https://doi.org/10.1016/j.ces.2024.121045.

H. John, S. K. Giri, L. K. Sinha, R. Pandiselvam, M. Sain, and A. Ray, “Investigating Flux Decline and Fouling Mechanisms in Ultrafiltration of Soy Protein Using a 10 kDa Hollow Fiber Membrane Module,” J. Food Process Eng., vol. 48, no. 5, p. e70113, 2025, doi: https://doi.org/10.1111/jfpe.70113.

A. Gul, J. Hruza, and F. Yalcinkaya, “Fouling and Chemical Cleaning of Microfiltration Membranes :,” Polimers, vol. 13, no. 4, p. 846, 2021, doi: https://doi.org/10.3390/polym13060846.

E. Melliti, B. Van der Bruggen, and H. Elfil, “Chemical inhibition of combined gypsum and iron oxides membrane fouling during reverse osmosis desalination process: Prevention and regeneration of membranes,” Desalination, vol. 551, p. 116414, 2023, doi: https://doi.org/10.1016/j.desal.2023.116414.

Y. Hata, Y. Bouda, S. Hiruma, H. Miyazaki, and S. Nakamura, “Biofilm Degradation by Seashell-Derived Calcium Hydroxide and Hydrogen Peroxide,” Nanomaterials, vol. 12, no. 20, 2022, doi: 10.3390/nano12203681.

Downloads

Published

03/01/2026

How to Cite

[1]
“Regenerasi Kinerja Fluks Membran PVDF Ultrafiltrasi Menggunakan Kombinasi Asam Sitrat & H2O2 Dalam Pengolahan Air Sungai Jagir”, jse, vol. 11, no. 1, Jan. 2026, Accessed: Apr. 27, 2026. [Online]. Available: https://jse.serambimekkah.id/index.php/jse/article/view/1452

Similar Articles

31-40 of 69

You may also start an advanced similarity search for this article.