Pengoptimalan Sistem Perpipaan Air Minum Perumahan Grand Residence City Kabupaten Bekasi

Authors

  • Alvin Bima Yutama Institut Teknologi Nasional Bandung Author
  • Mohammad Rangga Sururi Institut Teknologi Nasional Bandung Author

Keywords:

Kabupaten Bekasi, SPAM (Sistem Perpipaan Air Minum), Distribusi air bersih, EPANET 2.2

Abstract

Bekasi Regency has a population of over 3.2 million people, with a population density of 2,541 people/km² and an annual growth rate of 1.44%. The piped Water Supply System (SPAM) service coverage in the region has only reached 29.08%, slightly below the 30% target set in the 2020–2024 National Medium-Term Development Plan (RPJMN). Perumda Tirta Bhagasasi, the regional water utility, is striving to expand its service network, one of which is through the development of a distribution pipeline in the Grand Residence City housing area in collaboration with developer PT. Y. Planning was carried out for 2,514 housing units using hydraulic simulation software EPANET 2.2. The simulation results show that all nodes meet the minimum pressure requirement in accordance with Ministry of Public Works Regulation No. 27 of 2016; however, only about 4% of the links meet the ideal flow velocity due to the use of oversized pipe diameters. The headloss values remain within acceptable limits. Adjusting the pipe diameter is the primary solution to improve system efficiency. Furthermore, the region's low water consumption compared to the standard is attributed to limited and polluted raw water sources, along with a high leakage rate of 38%. Therefore, optimizing the SPAM pipeline network design is crucial to sustainably meet the clean water needs in Bekasi Regency.

References

[1] Badan Pusat Statistika Kabupaten Bekasi, "Kabupaten Bekasi Dalam Angka Tahun 2023," Badan Pusat Statistik Kabupaten Bekasi, 2023.

[2] PERUMDA Tirta Bhagasari Kabupaten Bekasi, "Data Air PERUMDA Tirta Bhagasari," 2024.

[3] BAPPENAS. "Bappenas pastikan pemda sediakan akses air minum layak bagi masyarakat." https://www.antaranews.com/berita/2105530/bappenas-pastikan-pemda-sediakan-akses-air-minum-layak-bagi-masyarakat (accessed 12 November 2024).

[4] PERUMDA Tirta Bhagasari Kabupaten Bekasi. "Realisasikan 10 Juta SR Air Minum, Pemerintah Gandeng Bank Dunia." (accessed 13 November 2024).

[5] Badan Pusat Statistika Kecamatan Setu, "Kecamatan Setu Dalam Angka Tahun 2023," Badan Pusat Statistik Kecamatan Setu, 2023.

[6] Badan Informasi Geospasial. "Peta per Wilayah." https://tanahair.indonesia.go.id/portalweb/download/perwilayah (accessed.

[7] A. Purnomo and A. N. Permata, "Perencanaan Sistem Distribusi Air Minum Zona Pelayanan Gresik Utara," Envirotek: Jurnal Ilmiah Teknik Lingkungan, vol. 11, no. 2, pp. 60-67, 2019.

[8] S. I. Wahyudi, "Sistem Pendukung Keputusan Penentuan Prioritas Pendistribusian Air Bersih Pada Daerah Krisis Air di Wilayah Kabupaten Bondowoso Menggunakan Metode Simple Additive Weighting (SAW)," 2017.

[9] P. G. P. Consultant, "Site Plan Pengoptimalisasi Jaringaan SPAM Perumahan Grand Residence City," Kabupaten Bekasi, 2024.

[10] T. J. McGhee and E. W. Steel, Water supply and sewerage. McGraw-Hill New York, 1991.

[11] A. S. Hidayat, "Penggunaan Webgis dalam Analisis Perubahan Urban Heat Island di Kabupaten Bekasi Tahun 2008–2018," Jakarta: FITK UIN Syarif Hidayatullah Jakarta, 2020.

[12] B. Syahputra, "Penentuan Faktor Jam Puncak dan Harian Maksimum Terhadap Pola Pemakaian Air Domestik Di Kecamatan Kalasan, Sleman, Yogyakarta," Jurnal Lingkungan Sultan Agung, vol. 1, no. 1, pp. 1-15, 2020.

[13] F. Yustiana and W. N. A. Maulana, "Perbandingan Metode Perhitungan Faktor Jam Puncak PDAM Tirta Rangga di Kecamatan Pabuaran - Kabupaten Subang," RekaRacana: Jurnal Teknil Sipil, vol. 7, no. 3, p. 213, 2021.

[14] Sahara, Siti, and Bayu Nurcahyo Adhi Nugroho. "Efektivitas penggunaan kereta listrik (KRL) Commuter Line Jabodetabek untuk mengurangi kemacetan di DKI Jakarta." EKONOMIKA45: Jurnal Ilmiah Manajemen, Ekonomi Bisnis, Kewirausahaan 10.2 (2023): 415-426.

[15] K. P. U. d. P. Rakyat, "Peraturan Menteri Pekerjaan Umum dan Perumahan Rakyat Nomor 27/PRT/M/2016 tentang Penyelenggaraan Sistem Penyediaan Air Minum," Jakarta: Kementerian PUPR, 2016.

[16] D. Martínez García, J. Lee, J. Keck, J. Kooy, P. Yang, and B. Wilfley, "Pressure-based analysis of water main failures in California," Journal of Water Resources Planning and Management, vol. 146, no. 9, p. 05020016, 2020.

[17] S. Sudarmadji, P. Puryanto, and H. Hamdi, "Pencegahan Terjadinya Pukulan Air Dalam Pipa Instalasi Plambing Pada Sistem Penyediaan Air Bersih," Pilar: Jurnal Teknik Sipil Politeknik Negeri Sriwijaya, vol. 7, no. 2, p. 158299, 2012.

[18] K. Abidin and S. Wagiani, "Studi analisis perbandingan kecepatan aliran air melalui pipa venturi dengan perbedaan diameter pipa," Dinamika, vol. 4, no. 1, 2015.

[19] A. Irvandi, D. R. Jati, and U. Kadaria, "Analisis Kehilangan Air Pipa Transmisi PDAM Tirta Sebalo Kabupaten Bengkayang," JURLIS: Jurnal Rekayasa Lingkungan Tropis Teknik Lingkungan Universitas Tanjungpura, vol. 2, no. 1, pp. 91-100, 2021.

[20] A. Pinandito, "Penentuan Ukuran Pipa Berdasarkan Laju Alir Maksimum Terjadi Erosi Dengan Persamaan Erosional Flow Pada Pipa Salur Sumur X Lapangan Y," Universitas Islam Riau, 2021.

[21] S. Nugroho, I. Meicahayanti, and J. Nurdiana, "Analisis Jaringan Perpipaan Distribusi Air Bersih Menggunakan EPANET 2.0 (Studi Kasus di Kelurahan Harapan Baru, Kota Samarinda)," Teknik, vol. 39, no. 1, pp. 62-66, 2018.

[22] A. K. Yahya, P. Rahayu, H. Ulia, and A. Y. Maulana, "Analisa Head Loss Dan Kerja Pompa Dengan Variasi Perubahan Diameter Pada Sistem Pemipaan," SAINTI: Majalah Ilmiah Teknologi Industri, vol. 19, no. 2, pp. 51-57, 2022.

[23] W. Waspodo, "Analisa Head Loss Sistem Jaringan Pipa Pada Sambungan Pipa Kombinasi Diameter Berbeda. Suara Teknik: Jurnal Ilmiah, 8 (1), 1–12," ed, 2017.

[24] Sudirman, Sudirman, and Harves Harves. "Analisa Headloss Aliran Fluida Pada Pipa Lurus Dengan Variasi Debit Aliran Dan Variasi Diameter Pipa." Jurnal Mekanova: Mekanikal, Inovasi dan Teknologi 8.2 (2022): 165-173.

[25] W. Laksono and A. Roihatin, "Analisa Headloss dan Estimasi Umur Pipa Water Injection pada Sistem Pompa Finish Mill Industri Semen," Jurnal Rekayasa Mesin, vol. 20, no. 1, pp. 73-80, 2025.