The energy cost at Perumda Air Minum Tirta Sewakadarma reached Rp452/m³, exceeding the national average of Rp380.13/m³. Despite this, no energy audit has been conducted in accordance with established standards. This study aims to conduct a preliminary energy audit and assess opportunities to enhance energy efficiency, particularly at the distribution pump of IPA Waribang II. The research involved primary data collection through field observations and secondary data. The audit revealed SEC of 0.23 kWh/m³, which is good. However, total pump efficiency was only 44.23%, below the recommended minimum of 60%. The distribution pump’s capacity exceeds the IPA, prompting manual adjustment of motor speed using VSD to 1,250 rpm, down from its maximum 1,480 rpm, to match IPA output of 150 L/s. The optimization could is by forming a subzone aligned with IPA capacity and automating the VSD based on demand fluctuations. Alternatively, the pump could be replaced with one appropriately sized for the IPA. The voltage imbalance is 0.33%, indicating stable power supply. The power factor is measured at 0.91 and could be improved to 0.99 using capacitor bank to avoid reactive power penalties.

Author Biographies

  • Maulana Nur Arif, Institut Teknologi Sepuluh Nopember

    Mahasiswa pada Departemen Teknik Lingkungan, Fakustas Teknik Sipil, Perencanaan, dan Kebumian, Institut Teknologi Sepuluh Nopember, Surabaya

  • Eddy Setiadi Soedjono, Institut Teknologi Sepuluh Nopember

    Dosen pada Departemen Teknik Lingkungan, Fakustas Teknik Sipil, Perencanaan, dan Kebumian, Institut Teknologi Sepuluh Nopember, Surabaya

References

[1] Pemerintah Kota Denpasar, Peraturan Daerah Kota Denpasar Nomor 7 Tahun 2019 tentang Perusahaan Umum Daerah Air Minum Tirta Sewakadarma. Denpasar: Pemerintah Kota Denpasar, 2019.

[2] BPS Kota Denpasar, Kota Denpasar dalam Angka. Denpasar: Badan Pusat Statistik Kota Denpasar, 2025.

[3] Kementerian Pekerjaan Umum, Kinerja BUMD Air Minum Tahun 2024. Jakarta: Kementerian Pekerjaan Umum, 2025.

[4] Kementerian Pekerjaan Umum dan USAID IUWASH, Pedoman Pelaksanaan Efisiensi Energi di PDAM. Jakarta: Kementerian Pekerjaan Umum, 2014.

[5] U. Sulung dan M. Muspawi, “Memahami Sumber Data Penelitian: Primer, Sekunder, dan Tersier,” Jurnal Edu Research, vol. 5, no. 3, hlm. 110–116, Sep 2024, doi: https://doi.org/10.47827/jer.v5i3.238.

[6] Perumda Air Minum Tirta Sewakadarma, Review Rencana Pengamanan Air Minum. Denpasar: Perumda Air Minum Tirta Sewakadarma, 2022.

[7] M. A. Siregar dan W. S. Damanik, “Pengaruh Variasi Sudut Keluar Impeler Terhadap Performance Pompa Sentrifugal,” Jurnal Rekayasa Material, Manufaktur dan Energi, vol. 3, no. 2, hlm. 166–174, Sep 2020, doi: 10.30596/rmme.v3i2.5278.

[8] S. Winarto, “Optimalisasi Energi pada Pompa Kali Solo I,” Swara Patra, vol. 9, no. 1, hlm. 58–72, 2019.

[9] K. H. Mendonça, H. P. Gomes, J. M. M. Villanueva, dan S. de T. M. Bezerra, “Performance Of Oversized Pumps Controlled By Variable Frequency Drives In Water Supply Systems,” Journal of Urban and Environmental Engineering, vol. 16, no. 2, hlm. 186–192, Apr 2021, doi: 10.4090/juee.2022.v16n2.186-192.

[10] D. O. W. Nugroho, T. Soehartanto, dan T. A. Wibowo, “Performance of Water Pump on Distribution and Transmission Process using Variable Speed Drive,” Journal of Engineering, vol. 6, no. 2, hlm. 2337–8530, 2020.

[11] National Electrical Manufacturers Association, NEMA MG-1: Motors and Generators. Washington, D.C.: National Electrical Manufacturers Association, 2009.

[12] A. Najmurrokhman dan Kurnia A., “Perancangan Electronic Load Controller Berbasis Mikrokontroler sebagai Stabilizer Tegangan dan Frekuensi,” Jurnal Teknik, vol. IX, no. 2, hlm. 99–109, Nov 2010.

[13] Winarso, “Perbaikan Kualitas Tegangan Menggunakan Dynamic Voltage Restorer (DVR),” Jurnal Ilmiah Foristek, vol. 3, no. 1, hlm. 236–241, 2013.

[14] D. A. Basudewa, W. Aribowo, M. Widyartono, dan A. C. Hermawan, “Analisa Penggunaan Kapasitor Bank terhadap Faktor Daya pada Gedung IDB Laboratory UNESA,” Jurnal Teknik Elektro, vol. 9, no. 3, hlm. 697–707, 2020.

[15] R. Y. D. Putra, S. Anam, dan F. Budiman, “Perancangan kVarh Meter untuk Metering Beban Induktif pada Jaringan Tegangan Menengah,” Undergraduate Thesis, Institut Teknologi Sepuluh Nopember, Surabaya, 2017.

Downloads

Published

22/07/2025

Issue

Section

Articles

How to Cite

[1]
“Audit Energi Awal Pada Pompa Distribusi IPA Waribang II Perumda Air Minum Tirta Sewakadarma Kota Denpasar”, jse, vol. 10, no. 3, Jul. 2025, Accessed: Dec. 22, 2025. [Online]. Available: https://jse.serambimekkah.id/index.php/jse/article/view/1076

Similar Articles

11-20 of 311

You may also start an advanced similarity search for this article.