Analisa Mikrostruktur Beton Menggunakan Air Bekas Wudu
Keywords:
concrete , ablution wastewater , compressive strength , XRD , FTIR, microstructureAbstract
This study aims to evaluate the effect of using ablution wastewater as a substitute for clean water on the compressive strength and microstructure of concrete. The analysis methods used include compressive strength testing, X-ray Diffraction (XRD), and Fourier Transform Infrared Spectroscopy (FTIR). The use of ablution water is considered an effort to conserve clean water resources while utilizing light wastewater from religious activities. Three concrete variations were tested: normal concrete, concrete mixed with 50% ablution water, and concrete mixed with 100% ablution water. The results showed an increase in compressive strength at 28 days of age, with values of 12.89 MPa, 13.78 MPa, and 14.25 MPa, respectively. XRD analysis indicated a reduction in calcium hydroxide (Ca(OH)₂) compounds and an increase in C–S–H and carbonate (CO₃²⁻) formations, suggesting a more optimal hydration process. FTIR results supported this, showing a decrease in hydroxyl (OH) groups and an increase in the absorption bands of Si–O and CO₃²⁻ groups. Overall, the use of ablution wastewater improves both the mechanical properties and microstructure of concrete. This innovation not only supports sustainability in civil engineering but also aligns with the spiritual values of Indonesia's Muslim community.
References
[1] Hepiyanto. R(1*), Kartikasari D. (2018). “Pengaruh Campuran Air Limbah (Air Selokan) Terhadap Kuat Tekan Beton f’c 14.5 Mpa (K-175)”, U kaRsT Vol.2, No.2, hlm.232-239. ISSN:2581-0855. http://dx.doi.org/10.30737/ukarst.v2i2
[2] Ansori.MA, Ridwan. A. (2019), ”Penelitian Uji Kuat Tekan Beton Dengan Memanfaatkan Air Limbah Tetes Tebu Dan Zat Additive Concrete,”Jurnal Manajemen Teknologi Dan Teknik Sipil, Vol.2, No.1, hlm.16-28. ISSN:2621-7686. http://dx.doi.org/10.30737/jurmateks.v2i1.388
[3] Badan Standar Nasional. (2000), ”Tata Cara Pembuatan Rencana Campuran Beton Normal. SNI 03-2834-2000,” Jakarta: Departemen Pekerjaan Umum
[4] SNELLINGS, R., 2018. Thermogravimetric analysis, in: SNELLINGS, R. (Ed.), A Practical Guide to Microstructural Analysis of Cementitious Materials. CRC Press, pp. 196–231. https://doi.org/10.1201/b19074-5
[5] Hoshino, S., Yamada, K., Hirao, H., 2006. XRD/Rietveld Analysis of the Hydration and Strength Development of Slag and Limestone Blended Cement, Journal of Advanced Concrete Technology.
[6] Mesecke, K., Warr, L.N., Malorny, W., 2022. Structure modeling and quantitative X-ray diffraction of C-(A)-S-H. J Appl Crystallogr 55, 133–143. https://doi.org/10.1107/S1600576721012668
[7] Suda, Y., Saeki, T., Saito, T., 2015. Relation between Chemical Composition and Physical Properties of C-S-H Generated from Cementitious Materials. Journal of Advanced Concrete Technology 13, 275–290. https://doi.org/10.3151/jact.13.275
[8] de Oliveira, A.M., Oliveira, A.P., Vieira, J.D., Junior, A.N., Cascudo, O., 2023. Study of the development of hydration of ternary cement pastes using X-ray computed microtomography, XRD-Rietveld method, TG/DTG, DSC, calorimetry and FTIR techniques. Journal of Building Engineering 64, 105616. https://doi.org/https://doi.org/10.1016/j.jobe.2022.105616
[9] Fraga, Y.S.B., Martins, G.L.O., Rêgo, J.H. da S., Terrades, A.M., Rojas, M.F., 2025. Investigation of the microstructure of Portland cement pastes with functionalized nanosilica with different contents of shrinkage-reducing additive. Constr Build Mater 462, 139991. https://doi.org/https://doi.org/10.1016/j.conbuildmat.2025.139991
[10] Badan Standardisasi Nasional, SNI 1974:2011 – Metode Pengujian Kuat Tekan Beton dengan Benda Uji Silinder, Jakarta: BSN, 2011.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Hapsa Nurika Sukardi, Mustakim, Abd. Muis (Author)