Evaluasi Pengolahan Limbah Cair Domestik pada Instalasi Pengolahan Air Limbah di Kota Bogor
Keywords:
Air limbah domestik, baku mutu air limbah, instalasi pengolahan air limbah, Kota BogorAbstract
The population growth in Bogor City is increasing every year, which can be seen from the population data from 2018 to 2022, increasing by 84,934 people with a population growth percentage of 2.07%. As the population grows, the demand for clean water will increase. This will also have an impact on the amount of domestic wastewater produced. In 2021, access to adequate sanitation in Bogor City will only be 75.35%, while it should reach 100% to achieve the SDG targets. Therefore, in order to achieve adequate sanitation, it is necessary to have a domestic wastewater treatment plant (WWTP) and assess IPAL so that the domestic wastewater produced can be safely discharged into the environment. A WWTP consists of several treatment units such as an intake building, an anaerobic pond, an aerobic pond, a facultative pond, a maturation pond and a sludge drying bed. The WWTP can be evaluated by comparing the effluent after treatment with quality standards, namely the Minister of Environment and Forestry Regulation No. 68 of 2016. The evaluation results show that several parameters still do not meet the quality standards for effluent to be discharged into the environment. These parameters are BOD and total coliform. Meanwhile, the percentage of TSS parameter removal was 57.14%, BOD 26.34%, COD 64.28%, Ammonia 69.88% and Total Coliform 99%.
References
[1] Astuti, Dwi, and Indri Rosemalia. "Penurunan BOD (Biological Oxygen Demand) Limbah Cair Domestik dengan Fitoremediasi." Jurnal Unitek , vol. 15(1), pp. 59-72, 2022.
[2] Badan Pusat Statistik, “Kota bogor dalam angka 2023”. Kota Bogor: BPS Kota Bogor., 2022.
[3] Bappeda Kota Bogor, Statistik Kota Bogor 2018. Kota Bogor, 2019.
[4] Busyairi,M., Dewi Y.P., dan Widodo D.I., “Efektivitas Kaporit pada Proses Klorinasi terhadap Penurunan Bakteri Coliform dari Limbah Cair Rumah Sakit X Samarinda,” Jurnal Manusia dan Lingkungan., vol. 23, pp. 156-162, 2016.
[5] Fadzry, N., Hidayat, H., & Eniati, E., “Analysis of COD, BOD and DO Levels in Wastewater Treatment Installation (IPAL) at Balai Pengelolaan Infrastruktur Air Limbah dan Air Minum Perkotaan Dinas PUP-ESDM Yogyakarta,” Indonesian Journal of Chemical Research , vol. 5, pp. 80-89, 2020.
[6] Karini, T. A., Wijaya, D. R., & Arranury, Z. F., “Karakteristik dan Kualitas Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Limbah Cair Rumah Sakit (Studi Deskriptif di Rumah Sakit X Kabupaten Jeneponto),” HIGIENE: Jurnal Kesehatan Lingkungan, vol. 6, pp. 100-107, 2020.
[7] Mallongi, Anwar, and Muh Fajaruddin Natsir. "Efisiensi pengolahan limbah cair industri tahu menggunakan biofilter sistem upflow dengan penambahan Efektif Mikroorganisme 4." Jurnal Nasional Ilmu Kesehatan vol. 1.2, 2018.
[8] Pangesti, F. S. P., & Ariesmayana, A., “Tinjauan Analisis Perhitungan Kebutuhan Air Bersih dan Air Limbah Untuk Perencanaan Sistem Penyaluran Air Limbah di Perumahan Bumi Ciruas Permai 1 Kabupaten Serang,” Journal of Sustainable Civil Engineering (JOSCE), vol 4, pp. 1-9, 2022.
[9] Peraturan Menteri Lingkungan Hidup dan Kehutanan Republik Indonesia, Peraturan Menteri Lingkungan Hidup dan Kehutanan (PerMenLHK) Republik Indonesia No. P.68/Menlhk/Setjen/Kum.1/8/2016 tentang Baku Mutu Air Limbah Domestik, 2016.
[10] Putri, Y.d., E. Yuliza, Lizadiawati. 2019. Kajian Kualitas Air dan Indeks Pencemaran di Perairan Kampung Sejahtera Pulau Baai Kota Bengkulu.
[11] Ratnani, R. D. "Kecepatan Penyerapan Zat Organik Pada Limbah Cair Industri Tahu Dengan Lumpur Aktif." Jurnal Ilmiah Momentum 7.2 (2012).
[12] Said, Nusa Idaman, dan Herlambang, “Teknologi Pengolahan Air Limbah,” BBPT, 2022.
[13] Sumangando, Adolfina, et al. "Analisis Kebutuhan Oksigen Biologi, Oksigen Terlarut, Total Suspensi Solit Dan Derajat Keasaman pada Air Limbah Rumah Sakit Pancaran Kasih Manado." Majalah INFO Sains, vol.3, pp. 45-50, 2022.
[14] Widayat, Wahyu, dan Arie Herlambang. "Penyisihan amoniak dalam upaya meningkatkan kualitas air baku PDAM-IPA Bojong Renged dengan proses biofiltrasi menggunakan media plastik tipe sarang tawon." Jurnal Air Indonesia, vol. 6.1, 2018.
[15] Widyaningsih, W., Supriharyono, S., & Widyorini, N., “Analisis total bakteri coliform di perairan muara kali wiso Jepara,” Management of Aquatic Resources Journal (MAQUARES), vol.5, pp. 157-164, 2016.
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Iren Chaerunnisa, Okti Dinasakti Nurul Mentari (Author)
This work is licensed under a Creative Commons Attribution 4.0 International License.